460 VAC, 3-phase, 60 Hz, constant run ECU
460 VAC, 3-phase, 60 Hz, constant run ECU Features:
Performance | |
Cooling BTU/Hr @ 80 deg F dry bulb, 67 deg F wet bulb, 95 deg F ambient | 38,000 |
Cooling BTU/Hr @ 80 deg F dry bulb, 67 deg F wet bulb, 120 deg F ambient | 34,900 |
Heating BTU/Hr | N/A |
Operating Conditions (deg F) | 50 to 150 |
Operating Conditions with Low Ambient Control ( deg F) | -30 to 150 |
Air Flow Rates (Evaporator Supply/Condenser Exhaust) (CFM) | 1200/3500 |
Sound Level (dBA) | 57 |
Electrical | |
Voltage (V) | 460 |
Phase | 3 |
Frequency (Hz) | 60 |
Maximum Nominal Current – Cooling (A) | 15 |
Maximum Nominal Current – Heating (A) | N/A |
Maximum Nominal Power Consumption – Cooling (kW) | 9.4 |
Electric Heat (kW) | N/A |
Breaker/Fuse Size (A) | 25 |
Supply Power Wire Size (AWG) | 12 |
Compressor Cycle | Constant Run |
Physical Characteristics | |
Dimensions (H x W x D) (in) | 45.75 x 34 x 45.5 |
Weight, unit (lbs) | 525 |
Weight, shipping (lbs) | 775 |
Fan Type, Evaporator | Direct Drive |
Fan Type, Condenser | Direct Drive |
Evaporator Return Air Duct Diameter (in) | 16 |
Evaporator Supply Air Duct Diameter (in) | 16 |
Refrigerant | |
Refrigerant Type | R-134a |
Titan GSE is YOUR total ground support equipment provider. We can customize any ground support equipment to suit your specifications.
460 VAC, 3-phase, 60 Hz, constant run ECU